• Horizontal Knee Type Disconnector (GW17)

Horizontal Knee Type Disconnector (GW17)

Type: High-voltage
Structure: Double-column Disconnector
Installation: Outdoor High-voltage
Phase: Three
Transport Package: by Wood Carton
Specification: IEC 62271-102: 2005 IEEE Std C37.30-1997
Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GW17
Trademark
Yong De
Origin
China
HS Code
85353000
Production Capacity
100PC/Month

Product Description

GW17 series Single-column Horizontal knee tpye Disconnector
It has the property of compact structure, advanced, clean appearance, beauty, Reliable property, economical.
It can compose "double static conductor" install way, spacing the covering. Especially, it adapt to main linking way is 3/2 power line and bus earth switch can be instead of the static contact.
Terminal block and conductive rod is made by casting aluminum alloy and aluminum alloy section, having the advantage of high-intensity, good flowing and good anti-corrosion.
Adapt to site's different laying way: One Line laying, 45° Laying, 135° Laying and so on
In the galvanic circle, the section is the combination structure made by screw fix linking, having the good property of stable flowing, high reliability, simple change way and convenient adding volume way.
In the galvanic circle, the contact and finger is made by T2Y pure copper tap whose connecting part is coated by 30μ M silver.
Finger spring is made by the stainless steel and its design is the inside hiding and outside press structure which is convenient for testing and changing
All the operating rod and linking rod are supplied by manufacturer, which is convenient for loading, adjusting and testing.
It can be supplied as a whole above the ground according to user's requirement.
No Item Technical parameter  
1 Rated Voltage                                  kV 72.5 123 145 245
2 Rated Current                                  A 1250.1600.2000.2500.3150.4000  
3 Rated Short Time withstand current and Time                                kA/s 25~50/4  
4 Rated Peak withstand current  kA 63~125  
5 1min power frequency   withstand voltage (effective value)    kV To earth 140 230 275 460  
To phase 140 230 275 460  
Across Isolating DS 180 300 315 605  
6 Lightning Impulse wishstand voltage
(peak value)        kV
To earth 325 550 650 1050  
To phase 325 550 650 1050  
Across Isolating DS 405 650 750 1200  
7 Rated mechanical terminal load            N Level of lateral load 750 1500 1500 2000  
Level of vertical load 500 1000 1000 1500  
Vertical 750 1000 1000 1250  
8 Capacity and Inductive Ability (open and close) Capacity Current  A 1  
Inductive Current  A 0.5  
9 Max Man Operative Moment    N. m 200  
10 Motor Drive operating mechanism control voltage                            V AC220; DC110, 220  
11 Motor Drive operating mechanism motor  voltage                                  V AC220, 380; DC110, 220  

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
148
Year of Establishment
2002-11-21