• Ploymer Housed Surge Arrester 39-51KV
  • Ploymer Housed Surge Arrester 39-51KV
  • Ploymer Housed Surge Arrester 39-51KV
  • Ploymer Housed Surge Arrester 39-51KV
  • Ploymer Housed Surge Arrester 39-51KV
  • Ploymer Housed Surge Arrester 39-51KV

Ploymer Housed Surge Arrester 39-51KV

Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Installation: Parallel Arrester
Application: Substation
Size: Meidum
Operation Voltage: High Voltage
Samples:
US$ 10/Piece 1 Piece(Min.Order)
| Request Sample
Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
YH10W5-51/134
Shape
Cuboid
Material
ZnO
Certification
ISO9001
Brand
Yongde
Breaking Capacity
High Voltage Circuit Breakers
Arc-Extinguishing Medium
Air
Housing
Polymer
Creepage Distance
2046mm
Transport Package
by Carton
Specification
IEC 60099-4
Trademark
YongDe
Origin
China
HS Code
85354000
Production Capacity
50000PCS/Year

Product Description

Ploymer Housed Surge Arrester 39-51KVPloymer Housed Surge Arrester 39-51KVPloymer Housed Surge Arrester 39-51KVPloymer Housed Surge Arrester 39-51KVPloymer Housed Surge Arrester 39-51KVPloymer Housed Surge Arrester 39-51KVPloymer Housed Surge Arrester 39-51KV39-51 KV Product's Characteristics:
The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance
Simple in structure, small in size and light in weight
Polymer Housed with flexible silicone rubber, explosion-proof
ZnO varistor as the core component is large in flow capacity which is much higher than that of the national standard GB11032 and ANSI 62.22, and with high reliability.
With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
Products with detachment device can provide signals for quitting operation when failure occurs, avoiding arrester explosion, and it is maintenance-free.
Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Type Maximum System Voltage(kV) Rated Voltage(kV) Continuous Operating Voltage(kV)   MRV under 1/5 μ s Steep Discharge Current(kV) MRV under 8/20 μ s Lightning  Discharge Current(kV)  MRV under 30/60 μ s Operating  Discharge Current  (kV) Line discharge class Long duration impulse current at 2mS(A) 4/10 μ s High Current Impulse(kA) Outside insulation standard(at IEC or ANSI) (kV)
IEC ANSI 5kA 10kA 5kA 10kA 0.5kA 1kA 2kA Lightning impulse withstand voltage kV Power frequency withstand voltage (kV)
Y5W, Y10W-39  
 
 
 
 
 
 
 
52
 
 
 
 
 
 
 
 
 
48.3
39 31.2 108 119 100 109 / / / 1 300 65 250 95 120/100
106 115 98 105 80.5 83 86.3 1 400 100
Y5W, Y10W-42 42 33.6 118 129.5 109 119 / / / 1 300 65 250 95 120/100
114.5 124 106 114 87 90 93.3 1 400 100
Y5W, Y10W-45 45 36 126 138 116 126.5 / / / 1 300 65 250 95 120/100
123.5 133 113 122 92.6 95.6 99.5 1 400 100
Y5W, Y10W-48 48 38.4 131 141 120 129.5 / / / 1 400 100 250 95 120/100
125.6 138.8 115.3 127.3 98.5 102 106 2 600 100
Y5W, Y10W-51 51 40.8 139.5 151.5 128 139 / / / 1 400 100 250 95 120/100
136 149 125 136.7 107 111 115 2 600 100
 Ploymer Housed Surge Arrester 39-51KV

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
148
Year of Establishment
2002-11-21