Line Use 96-120kv Ploymer Housing Moa Surge Arrestor with External Gap

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Low MOQ
The MOQ for the supplier's products is 1
Customization from Designs
The supplier provides design based customization services
ODM Services
The supplier provides ODM services
Customization from Samples
The supplier provides sample based customization services
to see all verified strength labels (27)
  • Line Use 96-120kv Ploymer Housing Moa Surge Arrestor with External Gap
  • Line Use 96-120kv Ploymer Housing Moa Surge Arrestor with External Gap
  • Line Use 96-120kv Ploymer Housing Moa Surge Arrestor with External Gap
  • Line Use 96-120kv Ploymer Housing Moa Surge Arrestor with External Gap
  • Line Use 96-120kv Ploymer Housing Moa Surge Arrestor with External Gap
  • Line Use 96-120kv Ploymer Housing Moa Surge Arrestor with External Gap
Find Similar Products

Basic Info.

Model NO.
YH5CX-96
Installation
Fixed
Application
AC/DC System
Size
Meidum
Operation Voltage
High Voltage
Shape
Cuboid
Material
ZnO
Certification
ISO9001
Brand
Yongde
Breaking Capacity
High Voltage Circuit Breakers
Arc-Extinguishing Medium
Air
Line Class
2
Voltage
96kv
Transport Package
by Wood Carton
Specification
Iec60099-4
Trademark
YongDe
Origin
China
HS Code
85354000
Production Capacity
500000PCS/Year

Product Description

96kv -120KV Main features of Surge arrester with external series gaps (for transmission line protection)
With smooth volt-second characteristic curve. Good insulation coordination and protective characteristics.
The electrical frequency withstand voltage is high in discharging gap, high reliability, low allocated voltage, minimum aging phenomenon.
Tube-like structure, injection hole to the side, overall injection molding polymer housed, no internal air gap, the core columns is encapsulated independently, with better air-proof performance than the other tubing products.
The injection hole to the side with a pressure release function.
The flow capacity of core component zinc oxide varistor reaches 100kA.
Good anti-fatique behavior with Polymer Housed products and a CTI level of six. Creepage distance meets the requirements of III level heavy pollution.
Type Nominal System Voltage Rated Voltage Minimum Reference Voltage under 1 mA DC Residual voltages at steep impulse current Residual voltages at lightning impulse 1.2/50 Impulse Discharge Voltage kV< =(+) Power Frequency Withstand Voltage 4/10 μ S High Current (KA) 2mS current /A
5kA 10kA 5kA 10kA
YH10CX-90/260 110 90 130   292   260 525 185 100     600
YH10CX-96/280 110 96 140   314   280 525 185 100 600
YH10CX-102/296 110 102 148   332   296 525 185 100 600
YH10CX-120/320 132 120 170   365   320 535 210 100 850