• 245kv Centre Break Disconnector (GW4-245/2500)
  • 245kv Centre Break Disconnector (GW4-245/2500)

245kv Centre Break Disconnector (GW4-245/2500)

Type: High-voltage
Structure: Three-column Disconnector
Installation: Outdoor High-voltage
Phase: Three
Transport Package: by Wood Carton
Specification: IEC 62271-102: 2005 IEEE Std C37.30-1997
Samples:
US$ 8000/Piece 1 Piece(Min.Order)
| Request Sample

Contact Supplier

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GW4-245/2500
Trademark
YONGDE
Origin
China
HS Code
8535300000
Production Capacity
100sets/Month

Product Description

GW38-40.5~252/630~4000 Type Three post Horizontal Double break disconnector
Double break is good for reducing the distance and station arranging, especially for indoor station
Because of electric rod's self-rotation and switching structure and having self-locking function, it has strong property of motor performance resistance. Meanwhile, it can resist motor, wind pressure, earthquake and other outside power
Contact and finger's on and off way is sliding rotation, having strong self-clean ability.
In the galvanic circle, the section is the combination structure made by screw fix linking, having the good property of stable flowing, high reliability, simple change way and convenient adding volume way.
In the galvanic circle, the contact and finger is made by T2Y pure copper tap whose connecting part is coated by 30μ M silver.
Finger spring is made by the stainless steel and its design is the inside hiding and outside press structure which is convenient for testing and changing
The bearing has changed from the bevel rear structure to the Universal connecting rod drive structure, having the advantage of simple structure, high intensity, convenient operation way and safety enough.
Bearing block is made by high-intensity casting steel (disposed by hot zinc coating), the height can be adjusted and have the function of damping.
Have different install way such as front install, side install, back install and leak 25° Install and so on, adapting to different station entering line ways.
All the operating rod and linking rod are supplied by manufacturer, which is convenient for loading, adjusting and testing.
It can be supplied as a whole above the ground according to user's requirement.
No Item Technical parameter
1 Rated Voltage                                  kV 72.5 123 145 245
2 Rated Current                                  A 1250  1600  2000  2500  3150  4000
3 Rated Short Time withstand current and Time                                kA/s 25~50/4
4 Rated Peak withstand current  kA 63~125
5 1min power frequency  withstand voltage (effective value)    kV To earth 140 230 275 460
To phase 140 230 275 460
Across Isolating DS 180 300 315 605
6 Lightning Impulse wishstand voltage
(peak value)        kV
To earth 325 550 650 1050
To phase 325 550 650 1050
Across Isolating DS 405 650 750 1200
7 Rated mechanical terminal load            N Level of lateral load 750 1500 1500 2000
Level of vertical load 500 1000 1000 1500
Vertical 750 1000 1000 1250
8 Capacity and Inductive Ability (open and close) Capacity Current  A 1
Inductive Current  A 0.5
9 Max Man Operative Moment    N. m 200
10 Motor Drive operating mechanism control voltage                            V AC220; DC110, 220
11 Motor Drive operating mechanism motor  voltage                                  V AC220, 380; DC110, 220

245kv Centre Break Disconnector (GW4-245/2500)
245kv Centre Break Disconnector (GW4-245/2500)
245kv Centre Break Disconnector (GW4-245/2500)

Send your message to this supplier

*From:
*To:
avatar Mr. Digang Ma
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Contact Supplier

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
148
Year of Establishment
2002-11-21