Substation Surge Protective Lightning Arrester for Lightning Protection System

Type: Metal Oxide Gapless Surge Arrester
Material: Silicone Rubber
Housing: Composite Housed
Poles Number: 1
Rated Voltage: 15 Kv
Delivery Time: 25 Days

Contact Supplier

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
YH5W5-15
Accessory
Bracket,Insulating Cap,Cooper Lead,Insulator,Hoop
Nominal Current
5 Ka
Color
Gray
Transport Package
Carton
Trademark
YongDe
Origin
Zhejiang, China (Mainland)
Production Capacity
45000 Piece/Pieces Per Month

Product Description

1. 0.28kV~500kV Surge Arresters' Characteristics: 
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight. 
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet. 
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free. 
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.

 

2. Surge Arrester Technical Parameters:

Type YH5W5-15/33    
Rated voltage---------kV 15 4/10μS High current impulse kA  65
MOCV  ----------------kV 12.7 Lightning impulse withstand kV 95
Nominal Current-------kV 5 Power frequency voltage withstand(dry/wet)kV 28
Residual voltage of steep impulse----at 5kA(kV) 43.5 0.1S TOV--------------kV 18
8/20μS Residual voltage of lightning impulse current kV(Peak value)-----at 5kA(kV) 40 1S TOV----------------kV 17.25
Residual voltage of switching impulse current kV (peak value)----at 1kA  (kV) / 10S TOV---------------kV 16.5
1mA D.C reference voltage (kV) 21.2 1200S TOV-------------kV 15
Line discharge level 1 Creepage distance ----mm 500
2mS long duration impulse current A 250 Material employed in series non-linear resistor Zinc Oxide


3. Surge Arrester Working Condition:

Environment temperature: -40--+40 degree
altitude:<1000m
48HZ<Rated frequency<62HZ
Power frequency voltage should not be more than continuous running voltage
Max wind speed should be less than 35m/s
Earthquake intensity should be less than 7 degree
If used in contamination area, should be noted in advance.

 

4. Other Surge Arrester

Substation Surge Protective Lightning Arrester for Lightning Protection System

Company Information

 

Hangzhou Yongde Electric Appliances Co.,Ltd was founded in 1993. We are one of the recommended model companies for national power grid of China. Our company is the professional manufacturer of 0.22KV-500KV metal oxide surge arresters, Zinc oxide varistors, 10-220KV outdoor disconnectors, earthing switches, composite insulators and fuse cutouts.


Yongde sticks to the quality policy of "being the technical forerunner, supreme in quality, supremacy of customers, and innovative progressing", so that our products and services successfully satisfy our users. We warmly welcome friends and customers from at home and abroad to contact us for exchange and corporation. We also welcome the feedback from our users.

Substation Surge Protective Lightning Arrester for Lightning Protection System

Packaging

 

Substation Surge Protective Lightning Arrester for Lightning Protection System

Certifications

Substation Surge Protective Lightning Arrester for Lightning Protection System

FAQ

 

Production Lead Time & Quality Guarantee:
1. Sample deliery time is about 2-3 days;
big order quantity is about 30-35 days after we receive 30%~50% deposit from you.
Generally, it takes 4 working days by DHL/UPS, and 7-10 days by EMS.
2. 12 months' warranty period. 20 years' quality guarantee period
With ISO9001:2008approvals.

Customer Services:
Our salesmen will reply your inquiry within 24 hours. Any order is welcome. If you like to be our agent in your country, we can give you any support on the technique & other aspects.

Send your message to this supplier

*From:
*To:
avatar Mr. Digang Ma
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Contact Supplier

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
148
Year of Establishment
2002-11-21